  Datasheet File OCR Text:
 Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
Features
* * * * * * Highly Integrated Downconverter Operates over 2.8 V to 5 V Supply Voltage Dual-Band and Triple-Mode Operation High Linearity, IP3 = 10 dBm typical Adjustable Gain and IP3 4 mm 20-Lead PQFN Plastic Package
MADCSM0001 V2
Functional Block Diagram
MODE SEL VDD CELL IFA IN MODE SEL CELL VDD CELL SRC
1
CELL MIX GND CELL IF OUT1 CELL IF OUT2 GND PCS IF OUT PCS SRC PCS LO IN GND PCS VDD GND CELL LO IN
Description
M/A-COM's MADCSM0001 is a downconverter suitable for Dual-Band and Triple-Mode Operation. The MADCSM0001 has a 50-ohm matched input, consumes low DC power and incorporates an on-chip switch that determines CDMA and AMPS mode select. The designer can tailor the linearity and gain performance of the MADCSM0001 according to the system needs. The MADCSM0001 is ideally suited for wireless applications where low noise, low current and high linearity are important features. The MADCSM0001 is fabricated using M/A-COM's 0.5-micron low noise E/D GaAs MESFET process. The process features full passivation for increased performance and reliability.
PCS IFA IN GND PCS MIX
Pin Configuration
Pin No.
1 2 3 4 5 6 7 8
Function
CELL MIX GND PCS IFA IN GND PCS MIX PCS LO IN GND PCS VDD GND CELL LO IN PCS SRC PCS IF OUT GND CELL IF OUT2 CELL IF OUT1 MODE SEL MODE SEL VDD CELL SRC CELL VDD CELL IFA IN
Description
Cellular Mixer RF Input/ Mixer IF Output DC and RF Ground PCS IFA Input DC and RF Ground PCS Mixer RF Input/Mixer IF Output PCS LO Buffer Input (-10 to -5 dBm) DC and RF Ground PCS Downconverter Supply Voltage. Must be RF bypassed DC and RF Ground Cellular LO Buffer Input (-10 to -5 dBm) Parallel RC network determines the PCS IFA Current, Gain and IIP3. PCS IF Out. VDD and IF matching required. DC and RF Ground Cellular IF Out2. VDD and IF matching required. Cellular IF Out1. VDD and IF matching required. Selects between Cellular IF Out1 and IF Out2 Mode Select Network Supply Voltage Parallel RC network determines the Cellular IFA Current, Gain and IIP3. Cellular Downconverter Supply Voltage. Must be RF bypassed. Cellular IFA Input
Ordering Information
Part Number
MADCSM0001 MADCSM0001TR MADCSM0001SMB
1
Package
Bulk Packaging 1000 piece reel Sample Board
9 10 11 12
1. Reference Application Note M513 for reel size information.
13
Absolute Maximum Ratings
Parameter
Voltage Input Power Operating Temperature Storage Temperature
2,3
14 15 16 17 18
Absolute Maximum
6V 0 dBm -30C to +85C -65C to +150C
2. Exceeding any one or combination of these limits may cause permanent damage to this device. 3. M/A-COM does not recommend sustained operation near these survivability limits. 1
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
19 20
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
Cellular Band - Electrical Specifications:
TA = 25C, Z0 = 50 , VDD = 3.0 V, MODE_SEL = 0 V / 3.0 V RF Frequency = 880 MHz, LO Frequency = 965 MHz, IF Frequency = 85 MHz
Parameter
LO Power Conversion Gain Noise Figure Input IP3 Return Loss
MADCSM0001 V2
Test Conditions
-- LO = -8 dBm LO = -8 dBm LO = -8 dBm RF Port LO Port IF Port LO to IF RF to IF LO = -8 dBm
Units
dBm dB dB dBm dB dB dB dB dB mA
Min.
-10 5 -- 5 -- -- -- -- -- --
Typ.
-8 10 8 10 12 25 17 13 28 10
Max.
-5 12 -- -- -- -- -- -- -- 15
Isolation Current
PCS Band - Electrical Specifications:
TA = 25C, Z0 = 50 , VDD = 3.0 V RF Frequency = 1960 MHz, LO Frequency = 1750 MHz, IF Frequency = 210 MHz
Parameter
LO Power Conversion Gain Noise Figure Input IP3 Return Loss
Test Conditions
-- LO = -8 dBm LO = -8 dBm LO = -8 dBm RF Port LO Port IF Port LO to IF RF to IF LO = -8 dBm
Units
dBm dB dB dBm dB dB dB mA
Min.
-10 9.5 -- 4 -- -- -- -- -- --
Typ.
-8 12 8 10 12 15 19 39 59 13
Max.
-5 14.5 -- -- -- -- -- -- -- 17
Isolation Current
Handling Procedures
Please observe the following precautions to avoid damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
Sample Board Schematic
MADCSM0001 V2
Recommended PCB Configuration
C17 L11 L2 L1 C1 C2 C13 L10 L8 R1 C7 L5 C6 L7 C8 C9 C11 C10 R2 C16 C15
C14 L9 C12
C3 L4 L6 L3 C4
C5
External Circuitry Parts List
Ref Designation
C1 C2,C3 C4 C5 C6,C7,C8,C12, C14,C15,C16,C17 C9 C10 C11,C13 L1,L11 L2 L3 L4 L5,L6 L7 L8 L9,L10 R1 R2
Value
2.7 pF 1000 pF 1 pF 2 pF 0.1 F 39 pF 12 pF 33 pF 22 nH 270 nH 6.8 nH 120 nH 5.1 nH 15 nH 33 nH 150 nH 56 Ohms 51 Ohms
Case Size
0402 0402 0402 0402 0402 0402 0402 0402 0603 0603 0603 0603 0603 0603 0603 0603 0402 0402
Purpose
RF Matching RF/IF Bypass RF Matching RF Matching RF/IF Bypass IF Matching IF Matching IF Matching RF Matching IF Matching RF Matching IF Matching RF/IF Matching RF Matching IF Choke IF Choke PCS Source Bias Cellular Source Bias
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001 V2
Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V
Conversion Gain (IF1)
12
+25C -30C +85C
Conversion Gain (IF2)
12
+25C -30C +85C
11
11
10
10
9
9
8 865
870
875
880
885
890
895
900
8 865
870
875
880
885
890
895
900
Frequency (MHz)
Frequency (MHz)
Input IP3 (IF1)
14
+25C -30C +85C
Input IP3 (IF2)
14
+25C -30C +85C
13
13
12
12
11
11
10
10
9
9
8 865
870
875
880
885
890
895
900
8 865
870
875
880
885
890
895
900
Frequency (MHz)
Frequency (MHz)
Noise Figure (IF1)
10
+25C -30C +85C
Noise Figure (IF2)
10
+25C -30C +85C
9
9
8
8
7
7
6 865
870
875
880
885
890
895
900
6 865
870
875
880
885
890
895
900
Frequency (MHz)
4
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
Frequency (MHz)
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001 V2
Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V
LO to IF1 Isolation
15
LO to IF2 Isolation
15
14
14
13
13
12
+25C -30C +85C
12
+25C -30C +85C
11 950
955
960
965
970
975
980
985
11 950
955
960
965
970
975
980
985
Frequency (MHz)
Frequency (MHz)
RF to IF1 Isolation
31
RF to IF2 Isolation
31
30
30
29
29
28
28
27
+25C
27
+25C
26
-30C +85C
26
-30C +85C
25 865
870
875
880
885
890
895
900
25 865
870
875
880
885
890
895
900
Frequency (MHz)
Frequency (MHz)
Current (IF1)
12
Current (IF2)
12
11
11
10
10
9
+25C -30C +85C
9
+25C -30C +85C
8 865
870
875
880
885
890
895
900
8 865
870
875
880
885
890
895
900
Frequency (MHz)
5
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
Frequency (MHz)
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001 V2
Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V
LO Port Match
0 -5 -10 -15 +25C -30C +85C
RF Port Match
5 0 -5 -10 -15 +25C -30C +85C
-20
-20
-25 -30 -35 929 954 979 1004
-25 -30 -35 844 869 894 919
Frequency (MHz)
Frequency (MHz)
IF1 Port Match
0 -5 -10 -15 -20 -25 -30 -35 70 75 80 85 90 95 100 +25C -30C +85C
IF2 Port Match
0 -5 -10 -15 -20 -25 -30 -35 70 75 80 85 90 95 100 +25C -30C +85C
Frequency (MHz)
Frequency (MHz)
6
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001 V2
Typical Performance Curves - PCS Frequency Band, LO = -8 dBm, VDD = 3.0 V
Conversion Gain
15
+25C -30C +85C
Input IP3
12
+25C -30C +85C
14
11
13
10
12
9
11 1930
1940
1950
1960
1970
1980
1990
8 1930
1940
1950
1960
1970
1980
1990
Frequency (MHz)
Frequency (MHz)
Noise Figure
9
LO to IF Isolation
41
40 8 39
38 7
+25C -30C +85C
37
+25C -30C +85C
6 1930
1940
1950
1960
1970
1980
1990
36 1720
1730
1740
1750
1760
1770
1780
Frequency (MHz)
Frequency (MHz)
RF to IF Isolation
61
+25C
Current
15
+25C -30C +85C
60
-30C +85C
14
59 13 58 12 57
56 1930
1940
1950
1960
1970
1980
1990
11 1930
1940
1950
1960
1970
1980
1990
Frequency (MHz)
7
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
Frequency (MHz)
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz
MADCSM0001 V2
Typical Performance Curves - PCS Frequency Band, LO = -8 dBm, VDD = 3.0 V
LO Port Match
0 -5 -10 -15 -20 -25 -30 -35 1660 1720 1780 1840 +25C -30C +85C
RF Port Match
0 -5 -10 -15 -20 -25 -30 -35 1870 1930 1990 2050 +25C -30C +85C
Frequency (MHz)
Frequency (MHz)
IF Port Match
5 0 -5 -10 -15 -20 -25 -30 -35 180 190 200 210 220 230 240 +25C -30C +85C
Frequency (MHz)
4 mm 20-Lead PQFN
Meets JEDEC moisture sensitivity level 1 requirements.
8
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
* North America Tel: 800.366.2266 / Fax: 978.366.2266 * Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 * Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.


▲Up To Search▲   

 
Price & Availability of MADCSM0001TR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X